Availability: In Stock
The System One 60 Series Bi-PAP has
Bi-Flex technology to make the use of a BiPAP machine slightly more comfortable
for the patient. Bi-Flex machines have two set pressures or in an Auto, they
have a minimum and a high along with a pressure difference setting. The means
that throughout the night, as your Expiratory Pressure increases, the
Inspiratory Pressure increases with it. The ability to track each breath allows
the machine to deliver pressure relief at three critical points in the
breathing cycle:
·
the transition
from exhalation to inhalation
·
the transition
from inhalation to exhalation
·
during exhalation
In many ways, the relief of pressure
on the exhalation allows you to have a more comfortable sleep while still
maintaining the necessary pressures to keep the airway open; therefore keeping
the oxygen levels more consistent and reducing events throughout the night.
Bi-Flex
Family Technology
Flex Technology is designed to enhance
traditional BiPAP therapy; maintaining effective therapy at comfortable
pressures. Users new to BiPAP equipment find that Flex Technology makes
adapting to therapy easier than typical BiPAP machines. The natural
breath-by-breath pattern enhances traditional therapy and improves compliance.
Bi-Flex makes the breathing cycle feel
natural and comfortable. Flex Technology allows the PR BiPAP Pro to track each
breath and provide pressure relief during three critical points in the
breathing cycle. Pressure is reduced by .5 increments during the transition
from exhalation to inhalation; inhalation to exhalation and during
exhalation.The Bi-Flex setting can be adjusted up to 1.5 H20 for maximum
comfort.
Advanced
Event Detection
The PR BiPAP Pro is designed to
identify symptoms beyond classic OSA parameters such AHI and flow limitations.
With the PR system, detection is expanding to include data on Snoring, Periodic
Breathing and Respiratory Effort-Related Arousals (RERAs). Along with digital
Auto-Trak Sensitivity and Flex Technology, the PR BiPAP Pro can detect the
breathing cycle and report any variation in breathing patterns, increasing
therapy effectiveness.
Digital Auto-Trak Sensitivity is the
brains behind Respironics' Flex Technology. A patented algorithm monitors
breathing patterns and responds to abnormal pressure changes. On the PR
BiPAP's, variable triggers and cycle thresholds are adjusted automatically to
provide effective sleep therapy.
Compatibility:
Any mask may be used with this machine. Tubing
is dependent on the Heated Humidifier you use with the machine. Example, Heated
Tube Humidifier has to use the Heated Tube (SYS1HT15), but the System One
Heated Humidifier can use any universal tubing.
Auto
Algorithm
Philips Respironics also has an Auto Algorithm
that maintains effective therapy at minimum pressures. What makes the REMstar
Auto algorithm so different? Unlike other algorithms, the REMstar Auto can
manage an event in the early stages rather than waiting for it to occur.
Because small degrees of flow limitations are usually present before the onset
of a complete obstruction or apnea, Philips Respironics' algorithm is designed
to proactively seek out these early indications and adjust pressure to resolve
an event before it occurs.
·
Proactive
Performance manages events in the early
stages of flow limitation, which leads up to an actual obstruction or apnea.
The Auto algorithm uses two airflow measurements to prevent pressures from
becoming too high: ('P'ressure Critical and 'P' Optimal).
·
Leak
Management is a comparison of average leak
rate and the expected leak from a CPAP mask. Encore records significant losses
above the expected leak rate as 'Large Leak' events and the BiPAP Auto reduces
therapy pressure to re-establish the mask seal, preventing false apneas.
·
Obstructive
Apnea is defined as events that reduce
80% of airflow for a minimum of 10 seconds.
·
Hypopnea is defined as events that reduce 40% of airflow for a
minimum of 10 seconds.
·
Flow
Limitation is measured through four
different baselines of the breathing waveform: Roundness, Flatness, Peak, and
Shape. Most other BiPAPs only take into account Flatness and Shape.
·
Snore or snoring can sometimes imitate a hypopnea event. Advanced
detection allows the PR BiPAP Auto to measure vibrations and partial airway
occlusions.
·
RERAs differ from a Hypopnea or snoring event in that a RERA shows
increasing respiratory effort with each breath, culminating in a shift in brain
wave activity and not necessarily a result of obstruction. Periodic breathing
conditions such as Cheyne-Stokes respiration and central apneas are
distinguishable from obstructed apnea or snoring events.
·
SmartRamp helps manage apnea events while users attempt to fall
asleep. Unlike other BiPAPs, the PR BiPAP Auto can react to an event during
Ramp Time.
Encore Data Management and Reporting
On-board memory has been added to the
BiPAP as well as storing information on a generic SD Memory card and reads
through any SD card reader. Use EncoreViewer Software to monitor therapy
effectiveness through a series of reports. A new Patient Flow and Event report
enables users to view a weekly breakdown on per-breath basis. Patient data is
used to identify particular conditions and events with specific colors.
System One Humidity Control (Optional) (Not
Included)
The
Philips Respironics BIPAP humidifier and water chamber are breakthroughs
for managing rain-out and water damage. System One Humidity Control technology
analyzes ambient temperature and patient airflow to reach relative humidity at
the mask. Sensors inside and outside the BiPAP machine closely monitor changes
in humidity and prevents condensation from forming inside the tube.
Dry
Box technology is advancement in reducing water damage to BiPAPs. The air
outlet port has been moved from the side of the humidifier onto the top. The
water chamber is outfitted with a one-way valve, between the machine and the
humidifier. System One with Dry Box makes it possible for the Philips Respironics
BiPAP machines to be truly spill-free.
System One Resistance Control
Respironics
wanted a machine to achieve optimal pressure regardless of whether the mask is
nasal, pillow, or full face. Resistance Control is the solution. A numbering
system on all of Respironics CPAP masks helps define the variable resistance
characteristics. Each number programs the BiPAP to compensate for different
mask types. The result? A consistent and reliable pressure enhanced with all
the benefits of Bi-Flex Technology no matter which mask is used.
Specifications:
Mode
of Operation: Auto
Bi-PAP or Fixed Bi-PAP
Warranty: 2 years
Special
User Features: Bi-Flex;
lighted LEDs
Pressure
Range: 4-25cm
Ramp
Time: 0-45 minutes (5 minute
increments)
Starting
Ramp Pressure: 4
to EPAP; patient adjustable
Device
Set-up: LCD/control
wheel/push button
Data
Storage Capacity (Min): 7-
and 30- day average, SD Card: > 1 yr, On board: up to 6 months
Data
Storage Content: Usage,
AHI, Leak
Compliance
Meter: Breathing
Detection
Altitude
Compensation: Automatic
Electrical
Requirements: 100
– 240 VAC
Humidifier: Integrates with System One
Heated Humidifier (DS6H) and/ or System One Heated Tube Humidifier (DS6T)
DC
Power: DC
Cable available for purchase
AC
Power: 100-240
VAC
Actual
Weight: 3
lbs.; 1.36 kg
Travel
Sized: 7"
x 5.5" x 4"; 18cm x 14cm x 10cm
Sound Level: 2.6 db (no humidifier; CFlex 0) to 4.2 db
(with humidifier; CFlex 3)

-620x620.jpg)
-120x120.jpg)